Installation & Assembly
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Mounting Screw
Driver
Fixture
Junction Box Screw
Mounting Backplate
Junction Box
Wire Connector
B1
C1
FIG.1
Back Plate Dimensions
9 1/4”
1 1/2”
1 3/4”
7 3/4”
INSTALLATION INSTRUCTION
27610 - Wall Sconce
WS-27610
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Secure the mounting back plate to the junction box using junction box screws (C1). The side of the mounting back plate marked
“GND” must face out.
4. Connect the Driver’s input/output wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground
wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
5. Insert the xture onto the mounting back plate from the top, and secure it with mounting screw (B1).
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
A1