INSTALLATION INSTRUCTION
746 - Outdoor Pendant
PD-W74615
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture,
including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area.
Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE Fig. 1
3. Remove the mounting screw (C1) from the xture.
4. Choose number of rods suitable for your application.
5. Thread the xture wire through the rods and canopy.
6. Connect the canopy, rods and xture body. Make sure all are tightened.
7. Secure mounting plate to the junction box using junction box screws
(B1).The side of the mounting platemarked “GND” must face out.
CONNECTING THE WIRES Fig. 2
8. Cut the extra wire. Connect the xture wires with junction box wires as
shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the
xture’s ground wire to it. Otherwise, connect the xture’s ground wire
directly to the mounting plate using the green screw provided. After
wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION (Fig. 2, 3, 4)
9. Place the glass to the bottom ring, put the top ring to the glass and
secure it by using two screws (D1).
10. Place the xture over the mounting plate and secure with
mounting screws (C1)
11. For slope ceiling application, rotate wire at the top of the stem to ensure
luminaries is aiming (Fig. 3).
12. To prevent the moisture from entering the outlet box and causing
a short, use clear caulking (i.e. indoor/outdoor silicone sealant)
to outline the outside of xture back plate (Fig. 4)
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Fig. 3
Turn to down
FIG.1
A1
C1
B1
D1
Wire Connector
Mounting Screw
Junction Box Screw
Screw
Canopy
1 x 6” Rod
3 x 12” Rods
Fixture
Glass
Bottom Ring
Top Ring
Junction Box
Mounting Plate
Back Plate Dimensions
GND
4 5/8”
1 3/4”
1 1/8”
1 3/8”
Ø4 3/4”
120°
Junction Box
Caulking
Fig. 4 Sealing