Installation Sheet

3
INSTALLATION INSTRUCTION

PD-44267
Oct. 2021Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Modern Forms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
White - Neutral
Black - Hot
Purple - Dim+
Gray or Pink - Dim-
Red - Fixture+
Black - Fixture-

9. This xture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specic
dimming wires information.
10. To utilize ELV or TRAIC dimming: use black (hot), white (neutral) and bare copper ground wires (ground).
11. To utilize 0-10V dimming: use purple (dim+), gray or pink (dim-), black (hot), white (neutral) and bare copper ground wires (ground).
NOTE: Make sure to connect 0-10V prior to power-up the xture in order to allow the 0-10V dimming to function properly.

12. Secure the xture to the mounting back plate using the mounting screw (B).
