Installation & Assembly

//
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
('0120%&-3
3. Remove the mounting screw (B) from the canopy.
4. The lamp can switch between three color temperatures (2700k-3000k-3500k), which can be adjusted to your preference with the switch in
the canopy (Fig.3).
5. Secure the mounting back plate to the junction box using standard junction box screws that comes with the junction box.
Note: (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting plate marked GND must face out.
')20%&+3
6. Connect the xture’s wires to junction box wires as shown (Fig. 2). Make sure that all wire connectors (A) are secure. If your outlet box
has a green or bare copper ground wire, connect the driver’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using  screw provided. After wires are connected, tuck them carefully inside the junction box.
(/4')44
7. Secure the xture to the mounting back plate using the mounting screw (B).
05
Black or
Smooth
05
White or
Ribbed
05
Bare wire
(Ground)

Black
(Hot)

White
(Neutral)

Green or Bare Copper
(Ground)
0%&+%
2
INSTALLATION INSTRUCTIONS
+,-.")
WS-26111

Phone (800) 526.2588
Fax (800) 526.2585

44 Harbor Park Drive
Port Washington, NY 11050

1600 Distribution Ct
Lithia Springs, GA 30122

1750 Archibald Avenue
Ontario, CA 91760

WS-26111
Back Plate Dimensions
10
5
8
4
1
8
1
3
8
1
3
4
0%&-
3000K3500K
2700K
0%&6
Junction box
Mounting plate
Wire connector
Junction box screw
Mounting screw
Fabric shade
(RPL-SHA-26111)
A
B
Ground wire
Diuser
(RPL-DIF-26111)
Glass
(RPL-GLA-26111)