14. Wall Control Operating Instructions (cont.)
Pairing
If you need to re-pair your fan or you want to pair a second wall control:
1. Power cycle your fan by turning o the power at the
circuit breaker.
2. Press and hold and buttons on wall control for
10-15 seconds.
3. The LED will blink green then remain solid green.
4. The green LED along with audible beeps will indicate
that pairing is successful.
5. Test wall control for functionality.
Unpairing
NOTE: Purging must be completed within 3 minutes of turning the power
on to the fan receiver.
1. When you re-engage power to the fans you want to purge, press and
hold the and buttons for 4 seconds.
2. The LED will alternate red/green, blink green, and the receiver will
beep to indicate that purging is successful.
Multi Location Wiring
1. Install the wall control using the wiring diagram below.
2. Individually pair each of the wall controls with the fan receiver using
the pairing instructions in the previous section.
NOTE: Pairing must be completed within 3 minutes of turning the power
on to the fan/receiver.
FIG.20
Fan
Line/Hot
Wall Controller 2
Wall Controller 3
Wall Controller 1
Neutral/White
If Applicable
Ground (Green or Bare)
Red
Fan
Line/Hot
Wall Controller 2
Wall Controller 3
Wall Controller 1
Red
If Applicable
Wall Controller 2
Ground (Green or Bare)
Neutral/White