Installation & Assembly
8 FR-W1910-52/62L
CAUTION: To prevent electrical shock, ensure electricity has been 
turned o at the circuit breaker before beginning.
If there isn’t an existing UL/cUL listed outlet box, please refer to the 
following instructions. Secure the outlet box directly to the building 
structure. Use appropriate fasteners and building materials. The 
outlet box and support structure must be able to fully support the 
moving weight of the fan (at least 35 lbs/15.9 kg). Do not use plastic 
outlet boxes. Use only UL/cUL listed outlet boxes marked 
“FOR FAN SUPPORT.”
Secure the outlet box directly to the building structure. 
Use appropriate fasteners and building materials. The outlet box 
and its support must be able to fully support the moving weight 
of the fan (at least 35 lbs). Do not use plastic outlet boxes.
Figures 1-4 are examples of dierent ways to mount the  
outlet box.
NOTE: To hang your fan where there is an existing xture but no 
ceiling joist, you may need an installation hanger bar.
NOTE: Downrod fans can be suspended up to a maximum 
recommended length of 72” using additional downrods 
(sold separately) and the included 80” lead wire.
NOTE: The sloped ceiling kit (sold separately) is required for sloped 
ceiling applications, and will accommodate slopes up to 45° (FIG.3).
NOTE: You may need a longer downrod to maintain proper blade 
clearance when installing on a steep, sloped ceiling (FIG. 3).
FIG. 1
Outlet Box
Outlet Box
Outlet Box
Provides Strong Support
Mounting Bracket
Recessed 
Outlet Box
SLOPED CEILING
MAX 30° ANGLE
FIG. 2
FIG. 4
FIG. 3
Joist
Support
Brace
5. Mounting Options