Installation & Assembly
4 FR-W1910-52/62L
1. Safety Rules
For operation, maintenance, and troubleshooting information, visit modernforms.com/help.  
1.  To reduce the risk of electric shock, ensure electricity has been 
turned o at the circuit breaker before beginning. 
2.  All wiring must be in accordance with the National Electrical 
Code “ANSI/NFPA 70” and local electrical codes. Electrical 
installation should be performed by a licensed electrician. 
3.  To reduce the risk of re, electric shock, personal injury or 
damage to the fan or other items, the outlet box and support 
structure must be securely mounted and capable of reliably 
supporting a minimum of 35 Ibs (15.9 kg). Use only UL/cUL 
listed outlet boxes marked “FOR FAN SUPPORT.” 
Use only the screws and washers provided with the outlet box. 
4.  The fan must be mounted with a minimum of 7 ft. (2.1m) 
clearance from the trailing edge of the fan blades to the oor  
and a minimum of 1.5 ft (0.5m) from the edge of the fan blades 
 to the surrounding walls. 
5.  Never place objects in the path of the fan blades.
6.  To avoid personal injury or damage to the fan and other items,  
please be cautious when working around or cleaning the fan. 
7.  To avoid electrical shock or damage to the motor or nish, 
do not use water or chemicals when cleaning the fan or fan 
blades. A dry cloth or lightly dampened cloth will be suitable 
for most cleaning. 
8.  After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box.  
The wires should be spread apart with the grounded 
conductor and the equipment-grounding conductor on one 
side of the outlet box, and the ungrounded conductor on the 
other side of the outlet box. 
9.  All set screws must be checked and re-tightened where 
necessary before installation. 