Installation & Assembly
20 FR-W1910-52/62L
14. Wall Control Operating Instructions (cont.)
Pairing 
If you need to re-pair your fan or you want to pair a second wall 
control:
1.  Power cycle your fan by turning o the power at the  
circuit breaker.
2.  Press and hold   and   buttons on wall control for 
10-15 seconds. 
3.  The LED will blink green then remain solid green.
4.  The green LED along with audible beeps will indicate 
that pairing is successful.
5.  Test wall control for functionality.
Unpairing 
NOTE: Purging must be completed within 3 minutes of turning the 
power on to the fan receiver. 
1.  When you re-engage power to the fans you want to purge, 
press and hold the   and  buttons for 4 seconds.
2.  The LED will alternate red/green, blink green, and the receiver 
will beep to indicate that purging is successful.
Multi Location Wiring 
1.  Install the wall control using the wiring diagram below. 
2.  Individually pair each of the wall controls with the fan receiver 
using the pairing instructions in the previous section.
NOTE: Pairing must be completed within 3 minutes of turning the 
power on to the fan/receiver. 
FIG.18
Fan
Line/Hot
Wall  Controller 2
Wall   Controller 3
Wall  Controller 1
Neutral/White
If Applicable
Ground (Green or Bare)
Red
Fan
Line/Hot
Wall  Controller 2
Wall   Controller 3
Wall  Controller 1
Red
If Applicable
Wall  Controller 2
Ground (Green or Bare)
 Neutral/White