Axis 52 Flush Installation Instructions works with the Google Assistant
Please read and save these instructions before installation DO NOT RETURN TO STORE 2 Axis Flush Instructions FH-W1803-52
General Inquiries For all questions about your ceiling fan please read all included instructions, installation procedures, troubleshooting guidelines and warranty information before starting installation. For missing parts or general inquiries call our trained technical staff at: 1-866-810-6615 option 0 MON-FRI 8AM-8PM EST Email: customerservice@modernforms.com Or live chat at modernforms.com Fan Support For fast service have the following information below when you call: 1. Model Name and Number 2.
Safety Rules For operation, maintenance, and troubleshooting information, visit http://modernforms.com/fan-support/ To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker before beginning. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70” and local electrical codes. Electrical installation should be performed by a licensed electrician. The fan must be mounted with a minimum of 7 ft. (2.
WARNING: Do not install or use your fan if any part(s) is/are damaged or missing. This product is designed for use only with the supplied parts and/or accessories designated for use with this product by Modern Forms . Substitution of parts or accessories not designated for use with this product by Modern Forms could result in personal injury or property damage and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are damaged or missing.
Get Smart... works with the Google Assistant Integrates seamlessly with: devices you already own Wet Location-listed to the strictest UL/cUL safety regulations.
Contents 1. Mounting Options 10 2. Installing the Mounting Bracket 10 3. Hanging the Fan 12 4. Attaching the Fan Blades 14 5. Making the Electrical Connections 14-16 6. Installing the Optional Wall Control 18 7. Finishing the Installation 20 8. Installing the Adapter Plate 20 9. Installing the LED Luminaire Module/Cover 22 10. Controlling the Fan 24 11. Reset 26 12. Breeze Mode 26 13. Application 26 14. Accessories 28 15.
Package Contents 1. Blade Set of 3 RPL-F1803-**-BD-** 7. Glass Shade RPL-F1803-GLA 2. Hanger Plate RPL-F1803-HGR 8. Luminaire Cover RPL-FH1803-COVER-** 3. Trim Ring - Decorative RPL-FH1803-TRIM** 9. Control Receiver w/Hardware F-R3-1803-** 4. Motor Assembly 5. Adapter Plate 6. LED Module F4IN-120V-R1-30 10.
Hanging Weight: 13 lbs MAC ID IMPORTANT: Please make note of the MAC ID on the receiver and keep it in a safe place.
1. Mounting Options CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning. If there isn’t an existing UL/cUL listed outlet box, please refer to the following instructions. Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and support structure must be able to fully support the moving weight of the fan (at least 35 lbs/15.9 kg). Do not use plastic outlet boxes.
1 1. 3 1 2 Support Brace 2. Outlet Box 3.
3. Hanging the Fan REMEMBER to turn off power at the breaker. Follow the steps below to hang your fan properly: 1. Disconnect power at the breaker to the fan location. Check your outlet box to make sure it has a proper Hot, Neutral, and Ground. If not, you will need to consult with a licensed electrician to install a new cUL/UL outlet box (Fig. 3). 2. Remove 1 of 2 screws from the bottom of mounting bracket and save for use in the Finishing the Installation section. Loosen the other screw (Fig. 3). 3.
3 3A 1 1 2 3 2 4 1. 120V Wires 2. cUL Listed Electrical Box 3. Mounting Plate 4. Mounting Screws (supplied with outlet box) 1. Screws 2. Top Assembly 3B 3C To Switch B A 1 2 3 (HOT) (Neutral) To Switch 4 3 Wood Screw 2. Safety Cable 3. Trim Ring 4. Top Assembly (Ground) *Bare or Green 1. 2 3 A PROPRIETARY AND CONFIDENTIAL (No Neutral) THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF .
4. Attaching the Fan Blades 1. Insert the blade through the slot in the housing. Align the holes in the blade with the fan motor assembly holes and secure with blade attachment screw with lock washers (Fig. 4). Use C hardware. 2. Repeat this procedure with the remaining blades. 5. Making the Electrical Connections WARNING: Installation of this fan requires that a three-conductor cable (including ground and neutral wires) which should run between ceiling and wall outlet box.
4 1. 1 Screws with Rubber Washers 2. Slot 2 3. Top Assembly 3 5 1 1. Motor Assembly 2. Receiver 2 3.
5. Making the Electrical Connections Motor to Receiver & Receiver to house supply wires (Fig. 5A). 1. Connect the motor assembly ground wire, mounting bracket ground wire and receiver ground wire to the ground wire in outlet box. WARNING: Failure to connect ground wires could result in poor fan control functionality. 2. Connect the red wire from the fan to the red wire marked “TO MOTOR” from the receiver. 3. Connect the grey wire from the fan to the grey wire marked “TO MOTOR” from the receiver. 4.
5A Outlet Box Black(Hot) can be RED from Switch leg Black(Line in H) GREEN(Ground) WHITE(Neutral) WHITE(Line in N) GREEN(GND Must Use) Receiver GREY(to Motor) YELLOW(to Motor) RED(to Motor) RED(to Motor) YELLOW(to Motor) BLUE (to Light) WHITE(to Light) GREEN(Hanger Assembly Ground) WHITE(Neutral) BLUE (for Light) GREY(to Motor) HARDWARE USED: D - Wire Nuts FH - W 1 8 0 3 -52 Axis Flush Instructions 17
6. Installing the Optional Wall Control NOTE: A Bluetooth wall control accessory can be purchased separately. 1. Connect the green wire marked “GROUND” from the wall control to the copper wire from the wall outlet box that feeds back to the circuit breaker – important for proper fan function (Fig. 6). 2. Connect the black wire marked “LINE IN” from the wall control to the black LINE VOLTAGE wire from the wall outlet box that feeds back to the circuit breaker (Fig. 6). 3.
6A 1 2 3 1. Wall Outlet 2. Wall Control 3. Wall Mounting Plate 4. Mounting Plate Screws 5. Wall Plate 4 5 Multi-location wiring Individually pair each of the wall controls with the fan receiver using the pairing instruction. See page 22.
7. Finishing the Installation 1. Secure all wire connections with supplied wire ties to assist in canopy installation. 2. Tuck connections neatly into ceiling outlet box. 3. Remove the motor from the hook on the mounting bracket. Slide the motor up to the mounting bracket and place the key hole on the motor over the screw of the mounting bracket (Fig. 7). 4. Turn motor until it locks in place at the narrow section of the key holes.
7 1 1. Screws 2. Mounting Bracket 2 3. Trim Ring 3 4. Motor 4 8 1 1. Mounting Ring 2.
9. Installing the LED Luminaire Module/Cover WARNING: Before starting installation, disconnect the power by turning off the circuit breaker or removing the fuse at fuse box. NOTE: If you do not plan to install the luminaire module with your fan at this time, skip to step 5. 1. Remove 3 screws from the outer perimeter of the adapter plate and keep for future use. 2. Raise and hold the LED luminaire module close to the adapter plate and proceed to secure the wire connections.
9 1. 1 Adapter Plate 2. LED Luminaire Module 2 9A 1.
10. Controlling the Fan Your fan was delivered to you with the included control already paired to your fan. A: Light On/Off, Bright/Dim B: Fan On/Off, Speed Up/Down C: Season (Summer/Winter) Air-Gap Switch: Pull tab to power off in case of emergency. Not necessary for normal fan operation (only included with wall control). NOTE: Your fan features 6 speeds. An audible tone will indicate when the speed is increased or decreased. When the fan has reached the minimum/maximum speed level the fan will beep twice.
10 10A A A B B C C Air-Gap Switch* Wall Control * Air-Gap Switch only included with wall control Remote Control Summer Mode Winter Mode (Counter-Clockwise) (Clockwise) 10B Fan On/Off Light On/Off Fan Direction Press and hold button for 4 seconds. Press and hold button for 4 seconds. Press and hold button for 4 seconds. Fan On/Off: Press and hold button for 4 seconds. The LED on the remote will flash green and all connected fans will beep to indicate the message has been received.
11. Reset If advised by fan support, you can reset your fan to factory settings by referring to (Fig. 11A) or (Fig. 11B). NOTE: If you change your Wi-Fi settings (SSID or Security Passphrase) you will require a Wi-Fi reset. Refer to Fig. 10 and then use the Modern Forms app to connect your fan to the new network. 12. Breeze Mode Breeze Mode mimics the natural ebb and flow of winds in nature by varying the fan speed. NOTE: Breeze Mode always rotates your fan in the Summer direction. 1.
10C 11 Pairing Unpairing Fan Wi-Fi Reset Press and hold buttons for 10-15 seconds To purge, press and hold buttons for 4 seconds Press and hold the and for 10 seconds until LED blinks green and receiver emits 2 long beeps 11B 11A Factory Reset Receiver Factory Reset Press and hold buttons for 10 seconds until the fan emits 3 beeps indicating the reset Press the reset button on the receiver until the receiver emits 3 beeps indicating the reset Scan and follow prompts for multilingual instructio
14.
15. Troubleshooting My Fan Will Not Start 1. Check main and branch circuit fuses or circuit breakers. 2. Check line wire connections to fan and switch wire connections in the switch housings. CAUTION: Make sure the main power is turned off! My Fan is Noisy 1. Allow for 24-hour break-in period. Most noises associated with a new fan will go away during this time period. 2. Check to make sure the screws which attached to the blades (and blade arms when applicable) are tight. 3.
15. Troubleshooting cont. My remote or wall control is not controlling my fan Verify that the fan is receiving power by power cycling the fan. To do this: 1. Cut power to the fan via standard On/Off wall switch, or the breaker if standard wall switch is not applicable. 2. Wait at least 10 seconds, and then restore power. 3. The fan will power on in Pairing mode for 3 minutes. 4. Press and hold (ICON) and (ICON) buttons on wall control for 10-15 seconds. 5.
My Fan failed to join the Wi-Fi network 1. Make sure you entered the correct Wi-Fi password and your mobile device is connected to the same network you attempted to connect the fan. 2. Make sure you are within the router manufacturer’s specified range. If all of these steps have failed - please power cycle your fan and router and retry. What is power cycling and how do I power cycle my fan? Power cycling is the act of temporaily removing the power source for your fan.
15. Troubleshooting cont. What is Pairing? Pairing is the process of connecting your Modern Forms remote or wall control to your fan. Your fan comes pre-paired to your included remote control. However, if you want additional controls for your fan or if you’re replacing a control, refer to the pairing and unpairing section of the instructions. What is a Factory Reset? Factory Reset is a restore of the fans original settings.
Certificate of Warranty Congratulations on your new purchase. Your new Modern Forms Smart Fan is engineered to make life easier every day. Modern Forms creates future-forward fans and luminaires that provide energy savings and outstanding efficiency. Our dedication to doing things the right way goes beyond our love for amazing products.
parte del distribuidor y, en consecuencia, cualquier daño consecuencial o costo de mano de obra que surja de un defecto se excluye expresamente. Esta garantía no se aplicará a los productos que hayan sido alterados, instalados incorrectamente, mal manejados o mal utilizados. La notificación de un defecto por escrito debe ser recibida por Modern Forms dentro de los cinco (5) años a partir de la fecha de compra (o según el período de tiempo indicado en el material).