Installation & Assembly
2 Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Shadow – Outdoor Sconce
WS-W46817 / WS-W46824
Plastic Anchor
Wire Connector
Junction Box Screw
WS-W46817 4 1/4"
7MBC241003 (17")
WS-W46817 9 1/2"
WS-W46824 5 1/4"
7MBC341302 (24")
WS-W46824 13 3/8"
Wood Screw
Mounting Screw
Gasket
Lamp Body
Junction Box
Ground Wire
White Wire
Black Wire
Mounting Back Plate
Driver (Canopy Inside)
Mounting Back Plate
E
A
B
F
C
D
PREPARATION
1. Shut o the power at the circuit breaker and remove
existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts
on a clear area. Be careful not to lose any small parts
necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (C) and gasket (D) from the
mounting back plate.
4. Drill holes in the wall aligned with the key hole located in
the mounting plate, insert the plastic anchor (E).
5. Secure the mounting back plate to the junction box using
junction box screws (B), fasten it to the wall using wood
screws (F). The side of the mounting back plate marked
“GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the driver’s input/out wires to junction box wires
as shown in Fig. 2, making sure that all wire connectors
(A) are secured. If your outlet box has a green or bare
copper ground wire, connect the xture’s ground wire to it.
Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are
connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION (Fig. 1/3)
7. Secure the xture to the mounting back plate using the
mounting screw (C) and gasket (D).
8. To prevent moisture from entering the outlet box and
causing a short, use clear caulking (i.e. indoor/outdoor
silicone sealant) to outline the outside of xture back plate
where it meets the wall. Leave a space at the bottom to
allow moisture to escape (Fig.3).
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
FIG. 1
Junction
Box
Caulking
Fig. 3 Sealing
1 3/8"
1 3/4"
G0