7. MAKING THE ELECTRICAL CONNECTIONS (cont.)
Motor to receiver electrical connections: (Fig. 13)
1. Connect the hanger ball/downrod assembly ground wire, mounting
bracket ground wire and receiver ground wire to the ground wire in
outlet box.
WARNING: Failure to connect ground wires could result in poor fan con-
trol functionality.
2. Connect the red wire from the fan to the red wire marked to motor” from
the receiver.
3. Connect the grey wire from the fan to the grey wire marked “to motor
from the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked “to mo-
tor” from the receiver.
5. Connect the white wire from the fan to the white wire marked “for light”
from the receiver.
6. Connect the blue wire from the fan to the blue wire marked “for light”
from the receiver.
FIGURE 13
White (neutral)
Outlet box
Black (hot)
Black (“AC IN L”)
Red (to motor)
Gray (to motor)
Yellow (to motor)
Yellow (motor)
Gray (motor)
Red (motor)
Receiver
Green (ground)
To hanger ball
Green (ground)
To hanger bracket
Green (ground)
White (for light)
White (for light)
Blue (for light)
Blue (for light)
White (“AC IN N”)
Green (ground)
Receiver to house supply wires electrical connections: (Fig. 13)
1. Connect the black (hot) wire from the ceiling to the black wire marked AC
in L from the receiver.
2. Connect the white (neutral) wire from the ceiling to the white wire
marked AC in N” from the receiver.