Specification Sheet

Ultra
Third-party lab tests conducted on the the UV-C technology used in ULTRA have shown a 99.99% reduction
of collectable active pathogen in the air and that the active SARS-CoV-2 virus, specifically, was not
detectable in the breathable air after 30 minutes of operation in an 8’x8’x10’ test room.
1
For larger spaces,
it is recommended to install multiple ULTRA fans. Whole room pathogen concentrations will vary between
installation locations, and the number of ULTRA fans installed.
UV
-C Module Maintenance
The ULTRA ceiling fan does not need frequent maintenance. A dry or lightly dampened cloth will be suitable
for most cleaning needs. Make sure you follow all safety rules contained in the instruction manual when
cleaning. DO NOT operate the ULTRA, including the UV-C Module, while performing any maintenance, repair
or replacement servicing the unit.
The UV-C Module (UVF7IN-120V-R1-MOD) has a 6,500-hour lifespan. The fan is equipped with a timer that
automatically tracks how much time the UV-C Module has been used. When there are approximately 80
hours remaining in the module’s life, the UV-C Module will flash when the ULTRA is turned on indicating that
you should replace the UV-C Module to ensure efficacy. Track and monitor use of the UV-C Module, avoid
unintended extended operation, to preserve the lifespan of the UV-C Module. See replacement module
instructions at modernforms.com for more information.
Troubleshooting
Please read the back of the instruction manual, visit modernforms.com, or contact our Fan Support team at:
1-866-810-6615 option 1 or fansupport@modernforms.com.
WARNING: Ultraviolet (UV) Radiation Hazard. The lamp in this The unit produces UV light. Skin or eye
damage may result from direct exposure to UV light. Avoid direct exposure to UV light. Always turn off and
disconnect power before servicing the unit. See Instructions for UV Safety Rules in the instruction manual.
WARNING: This product should be installed by a licensed electrician. This product should be mounted
to an outlet box UL-listed marked Acceptable for fan support” of 15.9 kg (35 lbs) or less and should use
mounting screws provided with the outlet box and/or support directly from building structure. Most outlet
boxes commonly used for the support of luminaires are not acceptable for fan support. Consult a licensed
electrician.
For further safety instructions, please refer to page 5 of the fan’s instruction manual (“UV Safety Rules”).
Disclaimer: While there may be information here or on our website relating to the effectiveness of the
UV-C technology incorporated in the ULTRA in reducing SARS-CoV-2 and other pathogens in the air, Modern
Forms makes no claims that its products can cure, treat or prevent any conditions, including COVID-19 or
other conditions that may be caused by airborne pathogens. Always consult your healthcare provider with
any health-related questions.
Whole room pathogen concentrations will vary between installation locations, and the number of ULTRA
fans installed, and it is not possible to predict the extent of reductions that will be achieved by the ULTRA in
whole room air in any particular room or environment. The ULTRA is not a substitute for good building air
exchange practices or manual cleaning and disinfection practices.
1
Based on tests conducted by an independent CAP and CLIA accredited lab, Innovative Bioanalysis. The report is available at
modernforms.com/ultra. The effectiveness of the ULTRA will vary based upon application and surroundings, including but
not limited to room dimensions and air flow.
modernforms.com/ultra