INSTALLATION INSTRUCTION
131 - LED Flush Mount
FM-13114
PREPARATION 
1.  Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2.  Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3.  Remove the mounting screws (C1) from xture. 
4.  Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).
5.  Connect the xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. 
If your outlet box has a green or bare copper ground wire, connect the xture’s 
ground wire to it. Otherwise, connect the xture’s ground wire directly to the 
back plate using the green screw provided. 
After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
6.  Secure the mounting plate to the junction box using junction box screws (B1), 
fasten it to the wall using wood screw (E1). The side of the mounting back 
plate marked “GND” must face out.
7.  Insert the PC diuser into the xture shade.
8.  Secure the xture onto mounting plate with mounting screws (C1).
Fixture Wires
Black or 
Smooth
Fixture Wires
White or 
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White 
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Plastic Anchor
Wire Connector
Wood Screw
Junction Box Screw
Mounting Screw
Fixture Shade
PC Diuser
Mounting Plate
Junction Box
Glass
(RPL-GLA-13114)
Shade
(RPL-SHA-13114)
D1
A1
E1
B1
C1
FIG. 1
Ø
7"
Back Plate Dimensions
GN
D
Ø
8 3/4"
Ø
2 3/4"
Ø
3 1/2"
FM-16818
168-LED Flush Mount
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive 
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center 
1750 Archibald Avenue 
Ontario, CA 91760
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
-  Read all instructions before installing.
-  System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
-  Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”  
  the circuit breaker switch(es) that control the power to the xture or room that you are working on.
-  Place the wall switch in the “OFF” position.
CAUTION
-  All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are 
  worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. 
  CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
-  Lisez toutes les instructions avant d’installer.
-  Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les 
  règlements locaux. 
-  Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt 
  (« OFF »). 
-  Placez l’interrupteur mural en position d’arrêt (« OFF »). 
MISE EN GARDE
-  Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté 
  et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du 
  luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. 
-  Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta 
  lámpara.
-  Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales. 
-  Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación 
  principal en la posición “OFF” (APAGADO). 
-  Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
-  Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni  
  utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación 
  ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTION
Slat - Vanities & Wall Sconces
WS-80618/WS-80624/WS-80636
Wire 
Connector
Qty: 3 pcs
7EAC112201
Mounting
Ring
Qty: 1 pc
7MBC101501
Transformer
Qty: 1 pc
5EN-2460-R2
Junction
Box Screw
Qty: 2 pcs
+ 1 Extra
7MPF0825C1
8-32x1 SS
Conversion
Plate
Qty: 1 pc
4MBA151110BA
Mounting
Screw
Qty: 2 pcs
+ 1 Extra
7MPF0415C2
8-32x9/16 SS
Set
Screw
Qty: 2 Extra
7MPF0308S1
5/32-32x5/16
Nickel Plating
Mounting
Anchor
Qty: 2 pcs
7TDD082401
Tapping
Screw
Qty: 2 pcs
7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
Junction Box
Mounting Plate
Fixture 
Shade
PC Diffuser
 Wire Connector
Plastic Anchor 
 Wood Screw
Junction Box Screw
Mounting Screw
 Glass
(RPL-GLA-13114)
 Shade
(RPL-SHA-16818)
Diffuser
(RPL-DIF-13114)
G0
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.  JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive 
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center 
1750 Archibald Avenue 
Ontario, CA 91760
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
-  Read all instructions before installing.
-  System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
-  Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”  
  the circuit breaker switch(es) that control the power to the xture or room that you are working on.
-  Place the wall switch in the “OFF” position.
CAUTION
-  All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are 
  worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture. 
  CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
-  Lisez toutes les instructions avant d’installer.
-  Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les 
  règlements locaux. 
-  Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt 
  (« OFF »). 
-  Placez l’interrupteur mural en position d’arrêt (« OFF »). 
MISE EN GARDE
-  Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté 
  et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du 
  luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. 
-  Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta 
  lámpara.
-  Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales. 
-  Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación 
  principal en la posición “OFF” (APAGADO). 
-  Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
-  Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni  
  utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación 
  ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTION
Slat - Vanities & Wall Sconces
WS-80618/WS-80624/WS-80636
Wire 
Connector
Qty: 3 pcs
7EAC112201
Mounting
Ring
Qty: 1 pc
7MBC101501
Transformer
Qty: 1 pc
5EN-2460-R2
Junction
Box Screw
Qty: 2 pcs
+ 1 Extra
7MPF0825C1
8-32x1 SS
Conversion
Plate
Qty: 1 pc
4MBA151110BA
Mounting
Screw
Qty: 2 pcs
+ 1 Extra
7MPF0415C2
8-32x9/16 SS
Set
Screw
Qty: 2 Extra
7MPF0308S1
5/32-32x5/16
Nickel Plating
Mounting
Anchor
Qty: 2 pcs
7TDD082401
Tapping
Screw
Qty: 2 pcs
7MPF2204J2
Ø4x22
A1 B1 C1 D1 E1 F1 G1 H1 I1
( C )
( C )
( E )
( D )
( B )
( A )
FM-70807/FM-70818
708-LED Flush Mount
A
B
C
Junction Box
Fixture
Wire Connector
 Mounting Screw
Mounting Plate
 Junction Box Screw
Driver 3 3/8"L x 2 3/8"W x 1 1/4"H
350°
60°
1 3/4"
1 3/8"
4 1/8"
4 3/16"
FM-70807 & FM-70818 Mounting 
Back Plate Dimensions
7. Secure the fixture to the mounting back plate using the mounting 
 screw (C).
5. Secure the mounting back plate to the junction box using junction 
 box screws (B). The side of the mounting back plate marked “GND” 
 must face out.
4. Remove the mounting screw (C) from the mounting back plate.
3. Put necessary silicon pad (1-4pcs) inside the wood lampshade if it is loose, as shown in Fig. 1.
COMPLETING THE INSTALLATION (Fig. 2)
MOUNTING THE FIXTURE (Fig. 2)
MOUNTING THE FIXTURE (Fig. 1)
6. Connect the fixture’s wires to junction box wires as shown in Fig. 3, 
 making sure that all wire connectors (A) are secured. If your outlet 
 box has a green or bare copper ground wire, connect the fixture’s 
 ground wire to it. Otherwise, connect the fixture’s ground wire 
 directly to the back plate using the green screw provided. After 
 wires are connected, tuck them carefully inside the junction box.
CONNECTING THE WIRES (Fig. 3)
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.
PREPARATION
Fixture Wires
Black or 
Smooth
Fixture Wires
White or 
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White 
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.3 Wiring
Fig.1
Fig.2
Wood 
lampshade
Fixture
Fixture 
assembly
+
Silicon pad