User`s manual

Preference variables located in INI and MPF files
ModelSim Xilinx Users Manual ModelSim Variables A-261
Explicit 0, 1 if 1, turns on resolving of ambiguous
function overloading in favor of the
"explicit" function declaration (not the
one automatically created by the
compiler for each type declaration)
off (0)
NoVitalCheck 0, 1 if 1, turns off VITAL compliance
checking
off (0)
IgnoreVitalErrors 0, 1 if 1, ignores VITAL compliance
checking errors
off (0)
NoDebug 0, 1 if 1, turns off inclusion of debugging
info within design units
off (0)
NoVital 0, 1 if 1, turns off acceleration of the
VITAL packages
off (0)
Hazard 0, 1 if 1, turns on Verilog hazard checking
(order-dependent accessing of global
vars)
off (0)
Quiet 0, 1 if 1, turns off "loading..." messages off (0)
CheckSynthesis 0, 1 if 1, turns on limited synthesis rule
compliance checking; checks only
signals used (read) by a process
off (0)
ScalarOpts 0, 1 if 1, activate optimizations on
expressions that dont involve signals,
waits or function/procedure/task
invocations
off (0)
[vcom] VHDL compiler control variables
Variable name Value
range
Purpose Default