The Default page includes these options:
• Default Radix
Sets the default radix for the current simulation run. You can also use the radix
(CR-81) command to set the same temporary default. A permanent default can
be set by editing the DefaultRadix
(A-263) in the modelsim.ini file. The chosen
radix is used for all commands (force
(CR-56), examine (CR-51), change (CR-34)
are examples) and for displayed values in the Signals, Variables, Dataflow, List,
and Wave windows.
• Default Force Type
Selects the default force type for the current simulation. Edit the
DefaultForceKind
(A-263) in the modelsim.ini to set a permanent default.
• Suppress Warnings
Selecting From IEEE Numeric Std Packages suppresses warnings generated
within the accelerated numeric_std and numeric_bit packages. Edit the
NumericStdNoWarnings
(A-264) in the modelsim.ini to set a permanent default.
Selecting From Synopsys Packages suppresses warnings generated within the
accelerated Synopsys std_arith packages. The permanent default can be set in
the modelsim.ini file with the StdArithNoWarnings
(A-265).
• Default Run
Sets the default run length for the current simulation. A permanent default can
be set in the modelsim.ini file with the RunLength
(A-265).
• Iteration Limit
Sets a limit on the number of deltas within the same simulation time unit to
prevent infinite looping. A permanent iteration limit default can be set in the
modelsim.ini file with the IterationLimit
(A-264).