User`s manual

Main window
7-120 ModelSim XE Graphic Interface ModelSim Xilinx Users Manual
Copy
copy the selected text
within the Main window
transcript
Edit > Copy see: "Mouse and keyboard
shortcuts in the Transcript and
Source windows"
(7-121)
Paste
paste the copied text to the
cursor location
Edit > Paste see: "Mouse and keyboard
shortcuts in the Transcript and
Source windows"
(7-121)
Restart
reloads the design
elements and resets the
simulation time to zero
File > Restart restart <arguments>
see: restart
(CR-84)
Run Length
specify the run length
for the current
simulation
none run <specific run length>
see: run
(CR-86)
Run
run the current simulation
for the default time length
Run > Run
<default_run_length>
run (no arguments)
see: run
(CR-86)
Continue Run
continue the current
simulation run
Run > Continue run -continue
see: run
(CR-86)
Run -All
run to current simulation
forever, or until it hits a
breakpoint or specified
break event *
Run > Run -All run -all
see: run
(CR-86), * see "Assertion
settings page"
(7-213)
Break
stop the current simulation
run
none none
Main window tool bar buttons
Button Menu equivalent Command equivalents