Technical data

Project file variables
420
-
System Initialization/Project File ModelSim EE/PLUS Reference Manual
IgnoreWarning 0,1 if 1, ignore assertion warnings
IterationLimit positive integer limit on simulation kernel iterations during one time
delta, default is 5000
License any single
<license_option>
controls Model
Sim
license file search; license
options include:
nomgc - excludes MGC licenses
nomti - excludes MTI licenses
vlog - only use VLOG license
vhdl - only use VHDL license
plus - only use PLUS license
noqueue - do not wait in license queue if no license
default is commented out
see also the
vsim
command (p91) <license_option>
NumericStdNoWarnings 0,1 if 1, warnings generated within the accelerated
numeric_std and numeric_bit packages are
suppressed, default is 0
PathSeparator any single
character
used for hierarchical path names, default in
modelsim.ini
is "/"
Resolution fs, ps, ns, us, ms,
sec - also 10x and
100x
simulator resolution; default is ns; this value must be
less than or equal to the UserTimeUnit specified
below; NOTE - if your delays are truncated, set the
resolution smaller
RunLength positive integer default simulation length in units specified by the
UserTimeUnit variable, default is 100
Start up = do<DO
filename>any
valid macro (do)
file
specifies the VSIM startup macro; default is
commented out; see the
do
command (p302)
StdArithNoWarnings 0,1 if 1, warnings generated within the accelerated
Synopsys std_arith packages are suppressed
[vsim] section
Variable name Value ran
g