Technical data

power report
ModelSim EE/PLUS Reference Manual Simulator Command Reference
-
343
power report
The
power report
command is used subsequent to the
power add
command
(p342). Data produced by these commands can be translated (by a Synopsys
utility) to drive the Synopsys power analysis tools. This command writes out the
power information for the specified signals or nets. The report can be written to a
file or to the Transcript window. Returns nothing.
Syntax
power report
[-all] [-noheader] [-file <filename>]
Arguments
-all
Writes information on all items logged. Optional.
-noheader
Suppresses the header to aid in post processing. Optional.
-file <filename>
Specifies a filename for the power report. Optional. Default is to write the report to the
Transcript window.
Description
The report format for each line is:
signal path, toggle count, hazard count, time at a 1, time at a 0, time at an X
toggle count is the number of 0->1 and 1->0 transitions
hazard count is the number of 0/1->X, and X->0/1 transitions
• times are the times spent at each of the three respective states
You will also need to know the total simulation time.
See also
power add
command (p342), and the
power reset
command (p344)