Technical data

toggle reset
ModelSim EE/SE Command Reference ModelSim Commands CR-155
toggle reset
The toggle reset command resets the toggle counts to zero for the specified nodes.
Syntax
toggle reset
[-all] [-r] [-in] [-out] [-inout] [-internal]
[-ports] <node_name>
Arguments
-all
Resets toggle statistic collection for all nodes that have toggle checking enabled.
Optional.
-r
Specifies that toggle statistic collection is reset recursively into subregions.
Optional; if omitted, the reset is limited to the current region.
-in
Resets toggle statistic collection on nodes of mode IN. Optional.
-out
Resets toggle statistic collection on nodes of mode OUT. Optional.
-inout
Resets toggle statistic collection on nodes of mode INOUT. Optional.
-internal
Resets toggle statistic collection on internal items. Optional.
-ports
Resets toggle statistic collection on nodes of modes IN, OUT, or INOUT.
Optional.
<node_name>
Resets toggle statistic collection for the named node(s). Required. Multiple names
and wildcards are accepted.
See also
"Toggle checking"
(E-447), toggle add command (CR-154), and the toggle report
command
(CR-156)