User Manual

HO Gauge DC/DCC
Steam Sound Decoder with
24 different chuff sounds
Item #0001823
with NMRA 8pin and 9pin connect
Thank you for purchasing our most advanced DC/DCC
locomotive sound decoder. Combined with any DCC
System or the MRC Blackbox, our true live capture digital
sound decoder will make your model railroad come to life.
24 types of synchronized chuff sounds
Double chuff enabling
1.5 amp capacity
34 different types of whistles and 7 types of bells
Programmable individual sound volumes
Programmable either 2-digit or 4-digit addresses
Programmable start voltage and top voltage
Programmable acceleration and decelaration rates
Programmable 14, 28, 128 speed steps
Supports full read back of address and CV values
Selectable factory default speed curve
Advanced speed table control CV67-CV94
Kick start voltage control CV65
Directional Head lights
Mars light and firebox flicker
28 accessory functions (F1-F28)
Supports full read back of CV’s
Supports advanced consisting (CV19)
Supports programming on the main (OPS mode)
Compatible with NMRA DCC standards
Complies with Part 15 of FCC Rules
28 mm speaker included
Dimensions: 40.0mm x 17.0mm x 6.5mm
PROGRAMMING
This decoder supports all program modes and read back features. With MRC
Prodigy Advance DCC you can read its address and all CV values.
Printed in USA
SPEED TABLE CV67-CV94 FOR 28 SPEED STEPS
When CV29’s bit 4 is set to “1” it will use the speed table formed by CV67-CV94
to control speed (motor voltage). It allows you to setup each speed for all 28
speed steps. First, program CV29 to 18 for short addresses (1-127) or program
CV29 to 50 for long addresses (128-9999) to enable speed table control. Then
select throttle to 28 speed steps and run your loco at speed step 1. Use program
CV on the main to change CV67’s value (1-255) to adjust step 1’s speed. The
kick voltage, CV65 is only applied when the speed step changes from 0 to 1. You
should switch between 0 to 1 many times to check step 1’s speed. When done
with CV67, select speed step 2 and program CV68. CV68’s value must be
greater then CV67’s. When done with CV67-CV94, use read back CV to make
sure their values are in increasing order.
Note: When using MRC Prodigy DCC to program addresses it will automatically
disable the speed table (set CV29’s bit 4 to “0”). Programming CV125 to 1 will
also disable the speed table and re-program CV67-CV94 to a default linear
speed setting.
TROUBLE SHOOTING
Loco runing without sound click F12 or Double click FO turn on/off
sound. Whenever the decoder doesn’t work please use the program
track to program CV #125 with value 1 to restore the decoder to factory
settings. This should bring the decoder to life with address #3. This
decoder should perform well with all DCC systems. The maximum DCC output
should be less than 21 V. If the locomotive does not respond to commands, it
may have lost its address. Please re-program the address and program CV19 to
0 (disable consist). If it responds slowly, you should clear its momentum by
reprogramming CV3 and CV4 to zero. If step 1’s speed is too high, you should
program start voltage, CV2 to zero. If its top speed is too slow, program top
voltage CV5 to 31. You should also clean the track to improve electrical pickup.
Read your DCC system manual to learn how to program and operate the decoder.
For more information about registers/CVs and their functions, please refer to the
NMRA DCC Standard & Recommended Practices, RP-9.2.2. This is available
directly from the NMRA or their website at www.nmra.org.
FCC COMPLIANCE
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions. (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interfer-
ence that may cause undesired operation.
RETURN PROCEDURE
This decoder carries a 6 month warranty against factory defects. This warranty
does not include abuse, misuse, neglect, improper installation, or any modifications
made to this decoder, including but not limited to the removal of the NMRA plug if
applicable. If it should become necessary to return the decoder for warranty repair/
replacement, please include a copy of the original sales receipt. Please
include a letter (printed clearly) with your name, address, daytime phone number,
and a detailed description of the problem you are experiencing. Please also include
a check or a money order for $8.00 to cover return shipping and handling. If the
decoder is no longer considered under warranty, then please include a check or a
money order for $29.00 to cover the cost of repair or replacement and return
shipping and handling. Be certain to return the decoder only.
Any questions regarding Warranty Policy can be directed to our Customer
Service Department by calling 732-225-6360 between the hours of 8:30am
and 6:00pm EST, or by emailing: rrtech@modelrectifier.com
Send the decoder to:
Model Rectifier Corporation
Attn: Parts & Service
80 Newfield Avenue
Edison, NJ 08837-3817 U.S.A
CV Register Description Range Default
CV1 R1 Short address 1-127 3
CV2 R2 Start voltage 0-32 0
CV3 R3 Acceleration 0-32 8
CV4 R4 Deceleration 0-32 8
CV5 --- Top voltage 0-32 32
--- R6 Page number --- ---
CV29 R5 Basic configuration --- 2
CV7 R7 Manufacturer version number --- 19
CV8 R8 Manufacturer ID --- 143
CV17 --- Long address upper byte 192-231 192
CV18 --- Long address low er byte 0-255 3
CV19 --- Advanced consist address 0-127 0
CV37 0=normal, 1=F3 and F4 exchange 0-1 0
CV39 0=normal, 1=F5 and F6 exchange 0-1 0
CV42 0=normal, 1=F8 and F12 exchange 0-1 0
CV49 Sound on/of f (1=on, 0=off, Whistle alw ays on) 0-1 1
CV50 --- Whistle type 0-33 4
CV 51 --- Whistle volume 0-3 3
CV52 --- Bell type 0-7 3
CV53 --- Bell volume 0-3 3
CV54 --- Bell ring rate 0-50 10
CV55 --- Chuf f type (12 types) 0-11 0
CV56 --- Chuf f volume 0-3 3
CV57 --- Brake squeal volume 0-3 1
CV 58 --- A ir release volume 0-3 3
CV59 --- Blow er hiss volume 0-3 3
CV60 --- Fire box door volume 0-3 3
CV61 --- Injector volume 0-3 3
CV62 --- Coupling volume 0-3 3
CV63 --- Air pump volume 0-3 0
CV64 --- Rail clack volume 0-3 3
CV65 Kick start voltage 0-63 63
CV67-94 28 speed steps table w hile CV29.4=1 1-255 linear
CV112 --- Conductor volume 0-3 3
CV114 Air pump type 0-3 3
CV115 --- Auto brake squeal enable/disable 0-1 1(enable)
CV118 Shoveling volume 0-3 3
CV119 --- Coupling fire volume 0-3 3
CV120 --- Chuff rate 0-40 20
CV121 --- Chuff start point 0-10 3
CV122 --- Double chuf f enable 0-1 1(enable)
CV124 --- Load control on/of f(1=0n. 0=off ) 0-1 0
CV 125 -- -
Factory def ault setting, program it to1 w ill restore
some CV to default settng
--- 0
CV 21 - -- 0
When CV 21=0, all accessory f unction w ill follow
its ow n address. When CV21=1, all f unctions w ill
follow the consist address
0-1