Co. Ltd. Modem User Manual
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
IP Module - CLI and Telnet Operation MN/CDM570L.IOM
17.2.9 Operations and Maintenance Page
The Operations and Maintenance page is activated from the Main Menu page.
The Operations and Maintenance page contains the following options/fields:
Menu Options/Fields Entry Description
Unit Uptime
Read
Only
Time in days, hours, mins and secs since the last time
the IP module was rebooted.
Unit Information
I
Displays unit current operational Software information.
IP Module Boot From
B
Determines which version of the IP Module software
package (includes Application, FPGA, and FFPGA) will
be loaded upon boot-up. The possible options are:
0. Latest - boot the newest software package based
upon date.
1. Image1 - boot the software package loaded into the
first slot in permanent storage.
2. Image2 - boot the software package loaded into the
second slot in permanent storage.
Base Modem Boot From
A
Determines which version of the Base modem firmware
will be loaded upon boot-up. The possible options are:
0. Latest - boot the newest software package based
upon date.
1. Image1 - boot the software package loaded into the
first slot in permanent storage.
2. Image2 - boot the software package loaded into the
second slot in permanent storage.
17–57