User manual
APPENDIX B – MAINTENANCE
23
ENGLISH
REPLACING THE
FLOW
RESTRICTOR
See Figure S:
1. Turn off MILLDROP and remove the mains cable.
2. Turn off the tap feeding the water to MILLDROP, remove the lid and the board
protection panel.
3. Lift and take out the filter assembly (A) from the brackets
4. Take out the osmotic membrane cartridge (B) and remove the red tube Ø6 from the
“flow restrictor” union (C).
5. Unthread the flow restrictor and replace it with a new one (see Hydraulic diagram in
Appendix D).
NOTE
REASSEMBLE THE FLOW RESTRICTOR UNION, AND SEAL USING “LOCTITE
5331” .
6. Restore the red tube Ø6 on the union, reassemble the osmotic membrane cartridge
and the filter assembly.
7. Connect the mains cable and turn on MILLDROP.
8. Open the water feeding tap and check for no leaks.
9. Reassemble the board protection panel and the lid, fasten the screws.
Figure S
RECYCLING /
DISPOSAL
INSTRUCTIONS
Milldrop equipment is mainly built from fiber-reinforced polymers, metals and electronic
components.
In case of disposal:
- Separate the various components according to the materials they are made of.
- Drop the equipment with a company specialized on recycling these products.
- Do not abandon the equipment in unsecured places.
- Always refer to current/applicable laws in the country of use.
A
B