INSTALLATION
14
4.
Install the drawing tap (with electric button) where desired (anyhow, near the
demineralizer).
5.
Plug the supplied pipe fitting on the drawing tap’s outlet, cut the silicone pipe
installed on the outlet C of the demineralizer so that it is long enough to reach
the pipe fitting of the tap, and tight by clamps.
NOTE
T
HE PIPING MUST NOT BE BENT, SQUASHED OR HAVE A PARTICULARLY TORTUOUS
ROUTE
. THE SILICONE TUBE’S LENGTH MUST NOT EXCEED 2 METRES, OTHERWISE
PERFORMANCE WILL BE QUALITATIVELY VERY LOW OR
, WHAT IS WORSE, THE
DEMINERALIZER ITSELF SHOULD MALFUNCTION
.
6. Connect the start/stop signal cable (provided with the demineralizer) between the
connector S on the demineralizer rear panel and the button connector of the tap.
Figure N
Clamp
Drawing tap
Silicone pipe
To the draining
siphon
Start/Stop cable
Pipe-union
(from the tap)
water inlet