User manual
INSTALLATION
7
ENGLISH
GENERAL
INSTALLATION
PRECAUTIONS
Obey the following warnings for the correct operation of the device and/or avoid
dangerous situations
:
- Install the demineralizer on a flat surface
;
- Leave adequate space for ventilation (at least 5 cm on the of the ventilation grid
side).
- Do not install near cisterns, wash-basins, etc. to avoid direct contacts with water or
liquids, possible short circuits and/or potentially dangerous situations for the operator;
- Do not install in excessively humid or poorly ventilated places;
- Do not install in places with gas or inflammable and/or explosive vapors;
- Install the unit so that the power cord is not
bent or crushed. It must run freely all the
way to the mains socket.
- Install the unit so that any external fill/drain piping is not
bent or crushed. The length
of the reinforced silicone tube connecting MILLDROP to the sterilizer or tank, shall
not exceed 2 meters, otherwise performance quality could fall or, what is worse, the
demineralizer itself could not operate properly.
ELECTRIC
CONNECTIONS
The demineralizer must be connected to a mains socket of adequate power for the
absorption required, and provided with ground connection in compliance with current laws
and/or standards.
The mains socket must be suitably protected by a circuit breaker having the following
characteristics:
- Nominal current 5 A
- Differential current 0,03 A
NOTE
THE MANUFACTURER WILL NOT BE LIABLE FOR DAMAGES CAUSED BY INSTALLING
THE UNIT ON INADEQUATE ELECTRICAL SYSTEM AND
/OR NOT GROUNDED.
If you need to replace the power cord plug, use a type of equal characteristics or, at any
rate, adequate to the equipment power requirements. The user is entirely responsible for
the choice and replacement of the plug.
DANGER
CONNECT THE POWER CORD DIRECTLY TO THE SOCKET.
DO NOT USE EXTENSIONS CORDS, ADAPTERS OR OTHER
ACCESSORIES.