Set up actions/messaging: Upon detecting an event, the MOBOTIX camera can trig-
ger alarms. These alarms can be adjusted to your needs and you can assign them
to a specific event: playing back an alarm sound on the camera speaker, showing
the visual alarm in the camera live image, sending an e-mail or network message
with the alarm image, placing a phone call, uploading an alarm image to an FTP
server, switching a signal output line of the camera (for example, for switching on
the lights/opening a door).
For the settings, see Setup Menu > Action Group Overview. The actions to be per
-
formed are defined and used in these action groups in the form of “action profiles.”
The dierent action profiles can also be defined in the following areas: Admin Menu
in the Hardware Configuration (profiles for signal output), Transfer Profiles (FTP, e-mail,
network messages) and Sound and VoIP Telephony (sound profiles, VoIP profiles). For
more information, refer to the online help for the Action Group Overview dialog box.
Activate shock detector: The S15 is also equipped with a shock detector as stan-
dard (for all IT and Secure models). If, for example, the cameras housing receives a
blow, it automatically registers it and sends a notification via a network message or
telephone call. A general advantage is that MOBOTIX cameras are extremely tough
because of the absence of mechanical moving parts. This allows them to stay fully
operational when they are subject to strong vibrations. Open the Setup Menu >
Event Control > Environment Events > Edit dialog box if you would like to activate
the shock detector (and any other sensors).
3.6.3 Settings When Using Thermal Sensor Modules
Before you start using thermal sensor modules, you need to register them with the camera
so you can access the settings that are specific to thermal image sensors.
In the camera’s browser interface, click on the Admin Menu button and in the Hardware
Configuration section, open the Image Sensor Configuration dialog.
Use the dropdown fields (Left Sensor, Right Sensor) to select the camera ports
(
External sensor Cam1
,
External sensor Cam2
) to which you will connect thermal
image sensors.
You can also use this section to select the sensor module (
External sensor Cam1
,
External sensor Cam2
) that will be shown at the left (Left Sensor) or at the right (Right
Sensor) in the dual image.
Close the dialog and save the configuration of the camera.
You can now configure the settings in the Setup Menu> Thermal Sensor Settings dialog
to your requirements.