Camera LEDs Flashing Pattern
M12
LED0 blinks red every three seconds
LED3 blinks red every three seconds,
synchronized with LED0
D12,
D14
LED0 blinks red every three seconds
LED3 blinks red every three seconds,
synchronized with LED0
Q22M,
D22M,
M22M
LED0 blinks green every three seconds
LED1 blinks red every three seconds,
synchronized with LED0
Q24M,
D24M,
M24M
LED0 blinks green every three seconds
LED1 blinks green every three seconds,
synchronized with LED0
Deactivating The Privacy Mode
Deactivate the mode under File | Privacy Mode or by clicking on the Privacy Mode button. This
requires that you use the same computer on which you activated the mode to deactivate it. If
you use another computer, enter the access data that you used when you activated the mode.
In an emergency (such as a total failure of the activating computer and a lack of access
data), the system can only be switched on if all integrated cameras are restored to their
factory default settings.
Resetting The Cameras To Factory Settings
1. Disconnect the power supply to each integrated camera.
2. Reconnect the power supply and hold down the camera keys for resetting to factory
settings until you hear the camera play a sound, as described in Section “Resetting
The Camera To Factory Settings“ in the Camera Manual.
Note
After resetting the cameras, the access data used prior to the activation of the
Privacy mode are again valid.
3. After you have reset all of the cameras, MxEasy will restart automatically.
4. Integrate all of the cameras that were previously integrated in the system.
5.
Load the automatic backup from the last program launch if it is available (see Section
4.6 “Saving The System Properties“). If the backup from the last system launch is not
available, then you must manually set all of the settings.