User manual

© MOBOTIX AG • Security Vision Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
110/144
MxEasy User Manual: System Configuration
Note
The counting lines should be within the detection areas. Otherwise, the computing time
increases, which reduces the frame rate of the camera and leads to imprecise results.
Defining Object Size
Specify the minimum object size for detection. This way, you can make sure that the camera
only analyzes objects that are relevant for you.
1. Click on the Object Size button. A predefined object size (yellow square) opens.
2. To adjust this square proceed as follows:
Use the mouse to drag the square to the desired position.
Drag the corner of the square using your mouse to increase or decrease its size.
3.
Click on the Object Size button to save the defined die definierten Bereiche zu speichern.
Activate the storage of the data generated once you have correctly set up MxAnalytics
and tested the settings.
4.5.3 Setting Up Storage For Future Evaluation
Movement data must be stored permanently in order to subsequently create and evaluate
MxAnalytics statistics and use the export function. To do this, it is necessary to configure and
format a MicroSD card accordingly. Configure storage in the MxFFS Volume Partitioning
dialog. To open it, click on the Format SD card button in the “MxAnalytics” tab. The dialog
contains the following areas
Format Mode: Select Quick Format if you know for certain that your camera is not
being accessed. Secure deletion mode requires significantly more time.