The MOBOTIX factory default is PoE class 2. This default is usually fine and nothing needs
to be changed. However, if the lower power level class 1 is sucient for your application,
it may due to possible internal power distribution schemes amongst the ports of the PoE
switch in use – be advantageous to change the PoE power level class in the browser:
1. Select Admin Menu > Network Setup > Ethernet interface
(for experts).
2. Under Power Supply, click Change.
3. A Power Wizard will appear to guide you through the PoE
configuration steps.
4. The camera will then need to be restarted via a hard reboot:
Disconnect the camera from the power supply, then reconnect
it, for example, by disconnecting and then reconnecting the
network cable at the PoE switch.
2.9.3 Power Supply Using A Switch
1. Connect the factory pre-installed cable of the camera to the Camera connector of
the PoE adapter.
2. Connect the LAN/Power connector of the PoE adapter to the Ethernet connector
of the switch/router or the Ethernet socket.
3. Plug the RJ45 connector of the power supply unit into the PC/Power connector of
the PoE adapter.
Variable PoE: multiple
cameras can be oper-
ated simultaneously
from the same switch
For the M24M, you
should use the new
blue MX-NPA-PoE-Set
- previous MOBOTIX
network power acces-
sories such as the NPA
Set, Power Box and
Power Rack (MX-NPA-
Set, MX-NPR-4 and
MX-NPR8/20) are
not suitable for use
with the M24M
The IP addresses in
the diagram are shown
only as an example
Switch/router
Adapter
(MX-NPA-PoE)
Power supply
LAN/www
PC
(10.8.0.11/255.0.0.0)
Camera
(10.8.0.99)
Camera
LAN/Power
PC/Power
RJ45
RJ45
RJ45