Manual

72
M16 Camera Manual: Installation
ConnectingthePatchCabletoanMX-Overvoltage-Protection-Box,MX-NPA-Boxor
Standard Network Port
First remove the blue bayonet catch and the blue sealing plug
in the right-hand connector on the box to establish the network
connection to an MX-Overvoltage-Protection-Box or MX-NPA-
Box. Then insert the MOBOTIX patch cable into the box and
secure the cable using the bayonet catch.
More information on installing an
MX-NPA-Box
or
an
MX-Overvoltage-Protection-Box
is available at
www.mobotix.com under
Product Selector > Accessories >
Interface Boxes.
Insert the MOBOTIX patch cable of the M16 into the network port for standard connections
(only permitted in indoor areas).
If additional cables are required inside the housing, they must be connected as described in
Section 2.2.6, «Connecting a USB Cable» and Section 2.2.7, «Connecting a Two-Wire MxBus*
Cable».
2.7.2 PowerSupplyUsingaSwitch
1. Connect the factory pre-installed cable of the camera to the camera connector of
the PoE adapter.
2. Connect the LAN/Power connector of the PoE adapter to the Ethernet connector of
the switch/router or the Ethernet port.
3. Plug the RJ45 connector of the power supply unit into the PC/Power connector of
the PoE adapter.
Patch cable
IP addresses in the
diagram are shown
only as an example
For the M16 you should use
the blue MX-NPA-PoE-Set
or the MX-NPA-Box – previ-
ous MOBOTIX network
power accessories, such
as the NPA-Set, Power-
Box and Power-Rack
(MX-NPA-Set, MX-NPR-4
and MX-NPR8/20) are not
suitable for use with the M16
Switch/router
PoE adapter
(MX-NPA-PoE)
Power supply
LAN/www
PC
(10.16.0.11/255.0.0.0)
Camera
(10.16.0.99)
LAN/Power
PC/Power
Camera
RJ45
RJ45
RJ45