Manual

116
M16 Camera Manual: Operating The Camera
Usingthiseventtype,youcancreateupto20eventproles,eachdeningameasurement
window within the image area. For every measurement window, you can set a minimum
range and a trigger value and you can decide if the event should trigger if the temperature
exceedsordropsbelowthespeciedvalue.Theminimumrangesetsthenumberofpixels
in the measurement window, which need to have a higher or lower temperature than the
triggervalueinordertotriggeranevent.Toconguretheneweventtype,.opentheSetup
Menu > Event Control > Event Overview dialog in the Environment Events section.
Notes
You can only use events of the type Thermal Radiometry if the sensor is running
in
linear mode
. To use this mode, open Setup Menu > Image Settings > Thermal
Sensor Settings and activate the Linear Mode option. Note that this has already
been set for sensors with TR technology as factory default.
If you want to use MxActivitySensor on sensors with TR technology, it is recom-
mended to set the value range of the measured temperatures in the Setup Menu >
Image Settings > Thermal Sensor Settings dialog to
Small (high sensitivity)
.
ImportantNotesonTemperatureMeasurement
The temperatures of objects in the image measured by thermal sensors is strongly
inuencedbythefollowingfactors(amongothers):
Surface texture and color of the objects
Distance between objects and the sensor
Atmosphere between objects and the sensor
Dependingonthedistanceandthescene,dierenttemperaturevaluesforthesame
object can be observed. In order to determine the proper trigger value, you can use
the new variables $(SEN.TTR.CELSIUS) and $(SEN.TTR.FAHRENHEIT) (see
Using Variables
inthecamera’sonlinehelp).
Forfurtherinformationonconguringandusingthermalsensors,pleaseseetheonline
help of the camera in the Setup Menu section under
Thermal Sensor Settings
and
Events
based on environment measurements
.