Datasheet
115/148
Connecting External Devices To The Door Station
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
Terminal Connector Functions (External Devices And Siedle Vario)
In addition to general technical specifications for the signal inputs and outputs, the table
also shows the precise layout of the 16-wire terminal connector when the external devices
are modules from the Siedle Vario series (see Section 2.9).
Board
General
Function
Siedle Vario Function Comment
MX- MxBus-
MxBus
Direct connection to camera
module
MX+ MxBus+
b Gnd Ground Reference potential
ERT HW
Signal from eLi/c (half-wave rectified)
Floor call when c fits eLi/c
Do Door opener
Relay switches b (door opener
still connected to c)
iLi Internal lights of Siedle modules
Relay switches b
(modules each
still connected to c)
eLi/c
Control for external light
(e.g., over the entrance door) Isolated relay (NO type)
eLi
Bpc Door lock switch (Bolt Position Contact) Contact switches c
Dpc Door contact (Door Position Contact) Contact switches c
Auth/S2 Transponder/Fingerprint Module switches c
PIR PIR module/motion sensor Module switches c
7.4 Bell button 4
Bell switches c (full-wave)
floor call switches ERT
(half-wave)
7.3 Bell button 3
7.2 Bell button 2
7.1 Bell button 1
8 x signal inputs 3 x signal outputs
Max. switching voltage: 50 V AC, 50 V DC
Max. current: 2 A
Max. load: 60 W
Max. input voltage: 24 V AC, 24 V DC
Min. input voltage: 5 V AC, 5 V DC
Min. current: 2 mA