User manual

3.1.3 Setting up the Network Parameters of the ExtIO for Ethernet Operation
In order to integrate the ExtIO into the target network, you need to specify proper
network parameters in the ExtIO (IP address, network mask, gateway). Please fol-
low these steps to perform this task:
1) Connect the ExtIO and your computer via a PoE switch.
2) Reset the ExtIO to factory defaults before you proceed (see section 3.1.4).
3) Set up your computer to run in a 10.x.x.x network, for example:
IP Address: 10.1.0.11, netmask: 255.0.0.0
Please see section 3.4.1,
Preparing the Ethernet Connection
, in the corre-
sponding
Camera Manual
for more detailed information on setting up a
computer to run on a
10.x.x.x network.
4) Open the user interface of the
ExtIO by entering the ExtIO's IP
address in the address field of
a browser (the factory default
password is meinsm).
5) Enter the future network parameters of the ExtIO (Network Setup > Ethernet
Interface section) or select BOOTP/DHCP > On to activate the automatic IP
address assignment from a DHCP server on the network.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
57/76
MOBOTIX ExtIO User Manual
PoE switch/router accord-
ing to IEEE 802.3af re-
quired
PoE IEEE 802.3af!
10.0.0.123
10.1.0.11
1:1 Patch-Cable
1:1 Patch-Cable