User manual

2.4.3 ExtIO Terminal Connector1 (Signal Inputs/Outputs)
Make sure that you are adhering to the applicable regulations in your country re-
garding the allowed cables when connecting the wires to the terminal connector.
Always observe the allowed wire dimensions (see table below).
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
32/76
MOBOTIX ExtIO User Manual
AWG: American Wire
Gauge (for measuring
cable diameters)
Terminal Part Name Remark
In2+
In2-
Signal input 2 Ext. sensor 2, max. 50V~/50V=
In1+
In1-
Out2+
Out2-
Signal input 1 Ext. sensor 1, max. 50V~/50V=
Signal output 2
Ext. device 2, 5V~ to 50V~ / 5V= to 50V=,
max. 100mA, max. 5W
Out1+
Out1-
Signal output 1
Ext. device 1, 5V~ to 50V~ / 5V= to 50V=,
max. 100mA, max. 5W
Allowed Wire Dimensions Solid AWG
Terminal connector 1
Cable diameters should be tailored to the electrical load and must follow the applicable regulations.
0.14 – 0.5 mm
2
26 to 20