Connecting the Patch Cable to an MX-Patch-Box, MX-NPA-Box or Standard
Network Port
First remove the blue bayonet catch and the blue sealing
plug in the right-hand connector on the box to establish the
network connection to an MX-Patch-Box or MX-NPA-Box.
Then insert the MOBOTIX patch cable into the box and secure
the cable using the bayonet catch.
More information on installing an
MX-Patch-Box
or
MX-NPA-
Box
is available at www.mobotix.com under Products>
Accessories > Interface Boxes.
Insert the MOBOTIX patch cable of the M15 into the network port for standard connections
(only permitted in indoor areas).
If additional cables are required inside the housing, they must be connected as described
in
Section 2.2.6, «Connecting a USB Cable»
and
Section 2.2.7, «Connecting a Two-Wire
MxBus Cable»
.
2.7.2 Power Supply Using a Switch
1. Connect the factory pre-installed cable of the camera to the camera connector of
the PoE adapter.
2. Connect the LAN/Power connector of the PoE adapter to the Ethernet connector
of the switch/router or the Ethernet port.
3. Plug the RJ45 connector of the power supply unit into the PC/Power connector
of the PoE adapter.
Patch cable
IP addresses in the
diagram are shown
only as an example
For the M15 you should
use the blue MX-NPA-
PoE-Set or the MX-NPA-
Box – previous MOBOTIX
network power acces-
sories, such as the
NPA-Set, Power-Box and
Power-Rack (MX-NPA-
Set, MX-NPR-4 and
MX-NPR8/20) are
not suitable for use
with the M15
Switch/router
PoE adapter
(MX-NPA-PoE)
Power supply
LAN/www
PC
(10.8.0.11/255.0.0.0)
Camera
(10.8.0.99)
LAN/Power
PC/Power
Camera
RJ45
RJ45
RJ45