3.2 LED STATUS INDICATORS
3.2.1 POWER LED
• The color of the power LED is set according to the percentage battery level remaining as follows:
o Green: Battery level remaining is greater than or equal to 40%.
o Yellow: Battery level remaining is less than 40% and greater than or equal to 20%.
o Red: Battery level remaining is less than 20%.
• The power LED stays on when the radio is on and blinks when the radio is off.
3.2.2 RADIO LED
• Slow short blinks: Attempting to register on network.
• Slow long blinks: Registered and Idle.
• Rapid blinks: Data transfer in progress.
4 FIRMWARE
4.1 FIRMWARE VERSIONS
1. BG96: BG96MAR04A04M1G
2. EFR32BG12: v1.4.1
3. BG96 DAM application: v1.4.1
5 OPERATING MODES
5.1 TEST (MAN UFACTURE) MODE
Description:
1. Used during factory testing, including PCBA test, partial assembly test, etc.
2. Supports certification activities as well as antenna performance tests (otherwise, a different mode should be defined)
Mode Entry Actions:
1. Enable all sensors for read/write functionality
2. Enable UART peripheral for factory test automation
3. Turn on all modules (where applicable): cellular Wi-Fi, GNSS
4. Customer production application is disabled