Owner's Manual

THE SELF PROTECTION
OF
YOUR INVERTER
Type
Possible
cause
If the output
Current I power exceeds
overload the rated output
power
10
to
15%.
Input
low
I Input voltage I
voltage
lower than 10.5V.
Input high I Input voltage
voltage higher
than
15V.
Over I The PCB
temperature temperature
is
around
230
°F.
How
do
you
know
if
the
protection
is
activated?
The inverter
will automatically
shut
off
,
RED
indicator lights
up
.
Solution
Remove all appliances
and unplug It.
Use smaller
power comsumption
appllances.
Remove all appliances
and unplug It.
Recharge the battery.
Remove all appliances
and unplug it.
Check the battery
voltage, make sure
it is within
11-1
SV
.
Remove all appliances
and unplug it.
Cool down for
15
minutes before
turning on again.
L:_
Remarks
Although the inverter has
protection against over load,
it may still damage the
inverter If the Input
voltage exceeds 16V.
Please ensure there is
ventilation in the
surrounding environment.