ACU-1000 Operations Manual
Interoperability Now 2-65
2.15.1.7 Restoring Factory Defaults:
In rare circumstances, there may be the need to completely restore the CPM-4 to the original
configuration that was established when the module was manufactured. The procedure for
doing this follows.
Equipment Required:
• Extender Card (supplied in the ACU-1000 Accessory Kit).
• ACU-1000
Procedure:
1. Power down the ACU-1000.
2. Remove the CPM-4 from the rack.
3. Install the extender card into the now empty slot.
4. Install the CPM-4 into the extender card.
5. Configure the “Restore Factory Defaults” jumper J16 [left to center]
6. Power up the ACU-1000.
7. Wait 15 seconds. (The LEDs will sequence…)
8. Power off the ACU-1000.
9. Remove the CPM-4 from the extender card.
10. Remove the extender card from the ACU-1000.
11. Re-install the bridging block on jumper J16- [right to center].
12. Install the CPM-4 back into the ACU-1000.
13. Finished.
...
J16
3 2 1
CPM-4
Ethernet
Connector
NORM
RESTORE
Figure 2-26 CPM-4 Restore Defaults Jumper Location