2-56 Interoperability Now
2.15.1.2.1 Configuration Screen Field Descriptions:
My IP Address:
The user may enter numeric text (0-255 decimal) into each of the four fields that define the
unique Internet Protocol address of the unit. Note: upon saving the changes, the user will need
to browse to the new address to continue configuration.
Subnet Mask:
The user may enter numeric text (0-255 decimal) into each of the four fields that define the
unique Internet Protocol mask of the unit. Note: upon saving the changes, the user will need to
browse to the new address to continue configuration.
IP Gateway:
The user may enter numeric text (0-255 decimal) into each of the four fields that define the
gateway address that the unit will use for resolving external network accesses.
Remote IP:
The user may enter numeric text (0-255 decimal) into each of the four fields that define the
unique Internet Protocol address of the remote VoIP unit that is paired with this unit. When the
CPM-4 is set up as a client, this is where the server’s IP address is entered. [This option relates
to the VoIP capability of the CPM-4 module.]
Baud Rate:
The pull down menu allows the user to configure the baud rate for the RS-232 serial port
located on the rear panel of the ACU-1000. Nine baud rates are available: 300, 1200, 2400,
4800, 9600, 19200, 38400, 57600, and 115200.
Serial Port Data Bits:
The pull down menu allows the user to configure the number of data bits for the serial port.
Two choices are available: 7 or 8 bits. The ACU Controller serial mode uses 8 bits.
Stop Bits:
The pull down menu allows the user to configure the number of stop bits for the serial port.
Two choices are available: 1 or 2 bits. The ACU Controller serial mode uses 1 bit.
Parity:
The pull down menu allows the user to configure the parity for the serial port. Three choices
are available: even, odd, or none. The ACU Controller serial mode uses “none”.