2.10.4.1 Flow Chart A Details DSP Setup Procedure
QA1 Are Templates Available?
To determine if there is a Template for the radio model being interfaced, double-click on any
DSP module icon to bring up its setting screen. Next, click on the ‘Load’ button to bring up the
list of radio templates.
(QA1 Yes) Initial Set Up Using Radio Template
If you are not sure if the radio and cable are configured per the Raytheon
Application Notes, do not click on the Template file to load it. Cancel and
click on the ‘Open App Notes” button to pull up the proper Application
Notes. If the provisions of the Application Notes can’t be followed, jump
ahead to the Basic Setup Procedure (Flow Chart B).
Click on the Template file that has the same name as the model of radio being
interfaced. All of the DSP settings will change to those listed on the Application Notes.
The Last Loaded / Saved field will list the name of the Template File.
Jump to QA3.
(QA1 No) Jump to QA2
QA2 Are Application Notes Available?
Application Notes are provided with radio interface cables purchased from Raytheon or may be
obtained from the Customer Service Department. If you do not currently have the proper radio
Template file, but do have Application Notes, proceed to step QA2 Yes. Otherwise jump to
flowchart B
(QA2 Yes) Application Notes but no Template File
Ensure that the radio and cable are configured per the Application Notes.
Set the DSP module to its default settings:
If each ACU Controller setting is marked [default], no action is necessary. Otherwise,
use the ACU Controller to set all to the Default position. Alternatively, all settings can
be quickly set to their default settings by loading the DSP Default Template.
Use the ACU Controller to change all DSP settings to those listed on the Application
Notes.
Click “Apply” to save the settings and stay in the Settings Mode.
Jump to Q3
(QA2 No) Jump to Flow Chart B
QA3 False Keying on Noise?