Instruction manual
ACU-1000 Operations Manual
2-84 Interoperability Now
2.16.2 System Programming Items
This section explains system programming items; they are used only to assist in the
configuration of other modules via the HSP-2A keypad.
2.16.3 Enter Programming Mode
Use the command * 9 9 to enter the programming mode. Once in this mode, the programming
of each individual module’s configuration items is possible. Unless otherwise specified, none
of the programming items listed in Table 2-17 or this section can be entered unless the ACU-
1000 is in the Programming Mode.
2.16.3.1 Controller Override
If the ACU-1000 is currently under remote control using the ACU Controller software,
programming via the HSP-2A is disabled. To override the console software and re-enable
programming via the HSP-2A, enter * 3 7 at the HSP-2A keypad. Configuration changes made
during console override will not be available at the console screen until the “Retrieve Current
Configuration” option is selected from the “File” pulldown menu.
2.16.3.2 Select a Module to Program
After entering the programming mode, use the command * 0 1 n n to select the slot number of
the module you wish to program, where nn is the two-digit slot number. For example, to
program the module in slot 5, enter * 0 1 0 5. After all programming commands are complete
for one module; the programming of another module may begin after using this command to
select that module. It is not necessary to exit and re-enter the programming mode each time a
new module is programmed.
2.16.3.3 Exit Programming Mode
When programming is complete, use the command * # to exit the programming mode and store
the configuration in non-volatile memory.
2.16.3.4 Reset Modules to Factory Settings
The command * 9 9 9 9 causes all modules in the ACU-1000 chassis to be reset to the factory
settings. Be careful, as using this command will erase all custom configuration programming.
This command can only be issued from programming mode.