Instruction manual
ACU-1000 Operations Manual
Interoperability Now 2-83
Note: The System Programming Items at the start of Table 2-17 are
system-wide programming commands that do not require the selection of
a module. To execute these items, enter the programming mode, but do
not select a particular module.
3. Now that a module is selected, begin actual programming. Enter the desired programming
command, following the format described in Table 2-18.
Continuing the example from step #2 above:
To set the receive level to 0 dBm on a DSP module located in extension 05, the user first
selects this module by entering * 0 1 0 5, the ACU then responds with “05 Ready”, the user
then sets the receive level to 0 dBm by entering * 0 2 3. The ACU responds with “Ready”.
4. When all parameters for a selected module are complete, another module can be chosen for
programming as in step #2 above, or the user can exit the programming mode at this time,
which will store all settings. This is accomplished by entering * #. The ACU responds
with “Saving configuration” followed by “Configuration has been saved”. Note: If the
programming mode is not exited by pressing * # before the power to the ACU is turned off,
none of the new configuration settings made will be saved.
Table 2-17 ACU-1000 System Programming items
System Programming Item Command N = Selection Factory
Enter Programming Mode
* 9 9
None
N/A
Console Override
* 3 7
None
N/A
Select Module to Program
* 0 1 n n
n n = slot extension (two digits must be entered)
N/A
Exit Programming Mode
* #
None
N/A
Reset Modules to Factory
Settings
* 9 9 9 9
None
N/A
Enable System PIN numbers
* 2 9 n
0 = Disable PIN numbers, 1 = Enable PIN numbers in
Priority operation, 2 = Enable PIN numbers in
Exclusive operation
Disabled
Program PIN numbers
* 3 0 nnnnx
nnnn is the four digit PIN, x is the security level from
0 to 9, 0 = not secure (PIN not required), 1=least
secure, 9 = most secure.
PIN
Database
Cleared
Delete PIN numbers
* 3 1 nnnn
nnnn is the four digit PIN
N/A
Set CPM-4 RS-232 Baud
Rate
* 5 4 n
n signifies the Baud Rate (see text)
115200
Stored Connections Auto
Restore at Power-up
* 5 5 n
0 = Feature is disabled
1 = Auto Restore is enabled.
Disabled