2.16 Programming Configuration Settings via the HSP-2A Keypad
Section 2.16.1 provides a quick step-by-step introduction into the use of the system
programming items and configuration items to configure a module via the HSP-2A keypad.
Refer to Table 2-17 for full list of these system programming items and also to Section 2.16.2
for an explanation of each item. Section 2.17 gives full explanations for each of the system
configuration options that may be programmed. Each type of module has a unique set of
configuration options that are used to optimize that module’s interface to the type of
communications medium it was designed for (for example, the DSP-2 module interfaces radios
and other 4-wire devices while the PSTN-2 interfaces 2-wire telephone systems). The various
configuration options are listed in Table 2-18.
2.16.1 Keypad Programming Instructions:
1. Enter the programming mode by pressing * 9 9 on the HSP keypad. The ACU-1000
responds with the voice prompt "Setup Mode". Each time a user successfully enters one of
the programming commands the ACU responds with “Ready”. The ACU-1000 stays in
programming mode until the user exits this mode by entering the * # (star pound) sequence.
The user does not have to enter * # until all programming is complete. The configuration
changes are not entered into non-volatile memory until the * # sequence is entered. All
programming configuration changes are then automatically stored in non-volatile memory.
These settings are retained unless new settings stored or a “Reset to Factory Settings
command is entered.
Note: If the ACU-1000 is currently operating under remote control via
either the Raytheon ACU Controller or WAIS Controller programs,
programming via the HSP-2A is disabled and the “Invalid Entry voice
prompt will be heard. To override console control, enter * 3 7 and wait
for the “Ready” prompt. Programming via the HSP-2A can then begin.
Any configuration changes made will not be seen via either controller
program until it executes the “Retrieve Current Configuration” command
from the “File” pulldown menu, or until it is terminated and restarted.
2. When in the programming mode, select the individual module you wish to program by
entering * 0 1 n n, where “n n” is the two-digit extension number of the module to be
programmed. The extension numbers will be from 01 through 12 in a single chassis system
and 01 through 24 in an expanded system, as the Master Unit in an expanded system
contains the programming configuration for the Expansion Unit. For example, to set a
parameter on a DSP module that is installed in extension 05, the user first enters the “Select
Module to Program” command * 0 1 0 5. Once this command is given user may then enter
as many configuration items as desired for the selected module. If the user mistakenly
selects an extension that is empty, or there is another reason why the selected module is not
valid for programming, the ACU-1000 will respond with an error message. There are no
configuration items for the HSP-2A module.