2.15.2.6.1 Configuration Page Field Descriptions:
Name:
The user may enter text in this field that identifies this DSP module. The name should uniquely
identify this unit, differentiating it from all other units on the network.
Unit is a:
The pull-down menu allows the user to choose either server or client mode. VoIP operation
requires pairing of clients and servers.
Communications Mode:
The pull-down menu allows the user to configure for either normal, broadcast, connectionless,
or multicast modes of VoIP communications.
VOIP Port:
The user may enter numeric text in this field (1-65535 decimal) defining which port to use for
the VoIP traffic.
Command Port:
The user may enter numeric text in this field (1-65535 decimal) defining which port to use for
network command traffic.
Serial Port Baud Rate:
The pull-down menu allows the user to configure the baud rate for the serial communication
channel on the DB-15 connector of the ACU-1000 slot. Nine baud rates are available: 300,
1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
Serial Port Data Bits:
The pull-down menu allows the user to configure the number of data bits for the serial
communication channel on the DB-15 connector of the ACU-1000 slot. Two choices are
available: 7 or 8 bits.
Serial Port Stop Bits:
The pull-down menu allows the user to configure the number of stop bits for the serial
communication channel on the DB-15 connector of the ACU-1000 slot. Two choices are
available: 1 or 2 bits.
Serial Port Parity:
The pull-down menu allows the user to configure the parity for the serial communication
channel on the associated rear-panel DB-15 connector. Three choices are available: even, odd,