Installation Guide
Document Name: iRISupply™ Installation and Assembly Guide
Published: 05/11/2004 Doc #: Version 2.0
Document Name: iRISupply™ Installation and Assembly Guide
Published: 05/11/2004 Doc #: Version 2.0
23
control cabinet. Use the hole nearest the cabinet
being connected.
Each service panel is connected to the frame by a
grounding wire (Figure 22). The grounding wire is a
green wire with yellow stripes. 4. Connect the antenna cables to the appropriate
connector on the multiplexer. The antenna cables
are connected sequentially to the multiplexer in
order of cabinet (A Æ E) and antenna cable number
(Lowest to Highest).
Figure 14 - Antenna Cable to Multiplexer Connection
5. The terminator is connected to the first port of the
multiplexer.
Figure 22 - Grounding Wire Connection
6. Cable 1 from cabinet ‘A’ will connect to the 2nd
BNC connector of the multiplexer (connector
number 2.) It will be followed by cables 2 through
5 (as appropriate and depending on cabinet type)
for cabinet A.
When reattaching the individual service panels, you
must ensure to reattach the grounding wire. Validate
that the connectors fit snuggly, by inserting the blue
connector into the white connector (Figure 23).
7. Once cabinet ‘A’ has been fully connected, cabinet
‘B’ will have its first antenna cable connected to the
next available BNC connector.
8. Connections are made to the main (upper)
multiplexer until no more ports are available. If
additional ports are required, additional
multiplexers (up to two) can be added below the
main MUX. Ports are populated from left to right as
described above and conforming to the information
provided in the previous table.
Figure 23 - Grounding Wire Connectors
18