Installation Guide
Document Name: iRISupply™ Installation and Assembly Guide
Published: 05/11/2004 Doc #: Version 2.0
2.3. Power Requirements
iRISupply™ requires a single** 120V/60Hz AC
grounded receptacle (Type 5-15R). Current draw is
less than 4.5 amps. For maintenance and service
requirements, a second Type 5-15R receptacle is
required.
**
WARNING:
Prior to installation and maintenance always unplug
iRISupply™ from the power outlet.
2.4. IT Requirements
iRISupply™ requires that all customer sites provide
LAN Connectivity as well as remote access capabilities.
2.4.1. LAN Connectivity
LAN Connectivity for iRISupply™ allows users to access
supply management data located within the control
compartment.
Table 1 - LAN Connectivity Requirements
Requirement Description
LAN
Connectivity
10/100 Base-T Ethernet, UTP5 cable
w/RJ45 connectors. One is required
for the iRISupply™. To assist with
installation and maintenance, a
second LAN connection is required.
Document Name: iRISupply™ Installation and Assembly Guide
Published: 05/11/2004 Doc #: Version 2.0
35
Figure 37 - System Properties Window
3. Click on the ‘Network Identification’ tab. On the
‘Network Identification’ tab click on the ‘Properties’
button (Figure 38).
**
If the cluster includes a powered standard auxiliary
cabinet(s), an additional outlet will be required for each
powered auxiliary cabinet.
Figure 38 - 'Network Identification' tab
6