User manual
Temperature range: working range –10°C to +55°C
storage range –25°C to +80°C
Weight: 78g (including battery)
Dimensions: 106 mm x 38 mm x 19 mm (LxWxH)
Operating Voltage: 3,45 Volt to 4,2 Volt (nominal 3,6 Volt)
Recharge time: approx. 40 Min. (for a fully discharged battery)
Standby-Time: up to 200 hrs. (telephone mode)
up to 160 hrs. (monitoring mode)
Module: Sagem M0110d
Battery: BAK 063448S2 Lithium Ion
Talk time: up to 120 min.
SIM-Card: 3 Volt
Frequency band: EGSM900 (880 to 960 MHz)
DCS1800 (1.710 to 1.880 MHz)
GSM-Class: Class 4 (2 Watt) as per EGSM900
Class 1 (1 Watt) as per DCS1800
Data Service: SMS
Mobi-Click is designed to the following standards:
GSM 03.03: “Digital cellular telecommunications system (Phase 2+); numbering, adressing and indentification“. Version 6.6.0.
GSM 03.13: “Digital cellular telecommunications system (Phase 2+); Discontinuous Reception (DRX) in the GSM system“. Version 6.0.0.
GSM 04.02: “Digital cellular telecommunications system (Phase 2+); GSM Public Land Mobile network (PLMN) access reference configuration“. Version 6.0.0.
GSM 04.03: “Digital cellular telecommunications system (Phase 2+); Mobile Station- Base Station System (MS-BSS) interface Channel structures and access capabilities“. Version 6.0.0.
GSM 04.04: “Digital cellular telecommunications system (Phase 2+); Layer 1 General requirements“. Version 6.0.0.
GSM 04.05: “Digital cellular telecommunications system (Phase 2+); Data Link (DL( layer General aspects“. Version 6.0.1.
GSM 04.07: “Digital cellular telecommunications system (Phase 2+); Mobile radio interface signalling layer 3 General aspects“. Version 6.5.1.
GSM 04.08: “Digital cellular telecommunications system (Phase 2+); Mobile radio interface layer 3 specification“. Version 6.11.0.
Further product information
Technical Data
Functions of the different sensors
How can I connect external sensors?
You can also connect external sensors to Mobi-Click. The connected sensor must operate with standards NO or NC. You can
connect as well simple short/open detectors. The defined mode allows you to choice type of the external equipment between
normally opened and normally closed.
Please find more information below.
SET
NO
(space)
Extern sensors activated.
Operational mode
of the sensor, loop
attached:
NO or NC
The instruction SET EXTERN NC will program
MC to give alarm when the external contact
will be opened for short period of time
(500 ms typical)
EXTERN
(space)
max. 2 meters
stereo plug, 2.5mm
2-wire cable
NO - normally opened
NC - normally closed