MMF POS Multi-Serial Interface Multi-Serial Interface Operator’s Manual May 1, 2010 MMF POS www.mmfpos.
MMF Multi-Serial Interface INTRODUCTION The MMF Multi-Serial Interface enables the cash drawer to be controlled by a serial RS-232 output port in the following configurations: • Standard serial dedicated; one cash drawer connected to the PC serial port. • Serial non-dedicated or daisy chain mode; two cash drawers can be connected to the same serial port or a serial peripheral can be connected to the cash drawer using the same serial port.
LED Signal Status Panel LED #4 (top-red) DTR / DSR / DCD Status; LED is ON when there is activity on any of these lines LED #3 (red) RTS / CTS Status; LED is ON when there is activity on any of these lines LED #2 (red) Drawer Status. Open / Close inner drawer indicator. LED #1 (green) Power good when ON solid / Data received when blinking Supply Voltage Power connector +12 VDC γ 5% 0.8 A. Plug required for Power connector: OD: 5.5mm γ 0.1mm ID: 2.1 mm γ 0.1mm Length: 8.75 mm γ 0.
Switch 1 POS When the indicated Switch is ON, all other specified Switches in the same column must be OFF SW1 SW1 CONFIGURATION CONSTRAINTS FUNCTION (when ON) 1 2 3 4 5 6 7 8 9 Loop DTR (pin 4) to DCD (pin 1) Loop DTR (pin 4) to DSR (pin 6) Loop CTS (pin 8) to RTS (pin 7) Receive Drawer-Open data input on TXD (pin 3) Receive Drawer-Open data input on RXD (pin 2) Receive Drawer-Open data input on CTS (pin 8) Send Drawer-Status output on CTS (pin 8) Send Drawer-Status output on RI (pin 9) -see JP1 S
Switch 3 “Dumb Mode” any open character based on the number of pulses within that ASCII character will open the cash drawer.
CONFIGURATION EXAMPLES Factory Default –This standard configuration is set so that any one (1) ASCII character will open the cash drawer and the RS-232 settings are auto-detected automatically by the cash drawer.
TEST PROCEDURE Factory Default – Any ASCII character will open drawer and RS-232 settings are auto-detected automatically by the cash drawer. Test from DOS: 1.- Configure theCOM port settings by typing: MODE com1:9600,n,8,1 The computer should return the following 2.
4.- CONFIGURE DRAWER “Add new drawer” called Cash_Drawer#1 5.- Type all the settings as illustrated on the configuration screen and click “OK” to save settings 6.- TEST DRAWER Click on “Initialize OPOS Drawer 1” then, click on “Open OPOS Drawer 1” the following message will be displayed: 7.- Click “OK” to the above message and then manually close the cash drawer. When the drawer is completely closed the following message will be displayed: 8.
CONFIGURATION EXAMPLES Daisy Chain two cash drawers –This serial non-dedicated configuration utilizes only one PC COM port to control two cash drawers. As a unique feature, each cash drawer can report the drawer Open / Close status independently. Serial Port Serial cable MMF P/N: 2261 99ND9F06 00 Use cable P/N: 226199ND9FA600 when connecting a serial peripheral Factory Default CASH DRAWER #1 (Primary) Connect 12V power supply.
TEST PROCEDURE Daisy Chain two cash drawers –This serial non-dedicated configuration utilizes only one PC COM port to control two cash drawers. As a unique feature, each cash drawer can report the drawer Open / Close status independently. Test from DOS: 1.- Configure the COM port settings by typing: MODE com1:9600,n,8,1 The computer should return the following 2.- To test the cash drawer type: copy con com1: A F6 The drawer should open and the PC will return the following 3.
4.- CONFIGURE DRAWER #1- To add the first device click on “Add new drawer” called: Cash_ Drawer#1. Select “Multi-Serial Interface” for dual cash drawer configuration. 5.- Type all the settings as illustrated on the configuration screen and click “OK” to save settings 6.- CONFIGURE DRAWER #2- To add the second device click on “Add new drawer” called: Cash_ Drawer#2. Select “Multi-Serial Interface ” for dual cash drawer configuration. 7.
8.- TEST DRAWER #1Click on “Initialize OPOS Drawer 1” then, click on “Open OPOS Drawer 1” the following message will be displayed: 9.- Click “OK” to the above message and then manually close the cash drawer. 1 When the drawer is completely closed the following message will be displayed: 2 10.- Click on “Uninitialize OPOS Drawer 1” and the test is complete. 11.- TEST DRAWER #2- Click on “Initialize OPOS Drawer 2” then, click on “Open OPOS Drawer 2” the following message will be displayed: 1 12.
CONFIGURATION EXAMPLES Interfacing with powered serial ports – The Multi-serial interface has the ability to receive power from the host and avoid using an external power supply for the cash drawer. This is only possible if the host has a powered serial port with the ability to supply 12VDC 800mA on pin#9. P3 JP1 must be placed on the PWR position (jumper across pins 3 and 2 of JP1) when receiving power via pin 9 from a PC powered serial port.