Service manual

3. Electrical Parts
3-38
3.3.9
Stop solenoid
SDG25S-6A7
SDG-006
SG06029E
SDG45S-6A6
(1) Specifications
Suction coil 41A
Holding coil 0.75A
(2) Function
Turning starter switch ON, voltage is applied to plus (+) terminal, and current flows to parallel
circuit of suction coil and holding coil to pull the plunger for stop solenoid at once. When the plunger
is pulled, the contact between plus (+) terminal and AUX (auxiliary) terminal turns OFF and sends
electricity to the holding coil only.
SG06030E
SG06031E
(37.2Ω)
(0.537Ω)