Service manual
3. Electrical Parts
3-33
SG05059
(2) Water temperature and glow time characteristics (Key OFF→ON)
Water temperature
Lamp lighting time t1
(seconds)
Pre-glow time t2
(seconds)
After glow time t3
(seconds)
Within
50±37°F (10±3℃)
8 30 30
More than
50±37°F (10±3℃)
0.3 0 0
(3) Chart of function
(st) st
Starter
Switch
t1
Lamp
t2 t4 t3
Glow
※1:(st) shows the chart of function at the location where the starter switch is positioned.
※2:In case that water temperature is less than 50±37°F (10±3℃), even after the preheating lamp
goes off, pre-glow continues 22 seconds.
However, when you start (cranking)(t4) engine during pre-glowing operation (t2), it will be
switched to the after-glow (t3) after engine starts.
※3:While engine is cranking(t4), preheating functions irrespective of water temperature.
(4)
Water temperature switch characteristics
OFF
※4:Upon installation, the screwing portion should be coated with
sealant “SEALOCK #10 THREEBOND”. Use torque wrench or
nut runner. (Do not use impact wrench influencing percussion.)
:25.3±3.6lbw・ft [34.3±4.9N・m (350±50kgf・cm)]
ST
ON
OFF
ON
OFF
ON
OFF
※1
※2
ON
50±37°F (10±3℃)
37°F (3℃) MIN
※4
※3