Service manual
2. Overhauling
2-12
(2) Check the gap between the cooling fan and fan shroud
Maintain an adequate gap in both the vertical and horizontal directions.
If the fan is mounted incorrectly so that it leans toward one side wall of the shroud,
leading to a smaller gap in one direction, the fan may produce abnormal noise due to
rubbing against the shroud during starting or stopping and may also overheat.
SG05050
Gap size Unit : in. (mm)
SDG25S
-6A7
SDG45S
-6A6
SDG65S
-6A6
SDG100S
-6A6
SDG125S
-6A6
SDG150S
-6A6
Fan outer diameter
(a)
16.9 (430) ← 19.7 (500) 22.8 (580) 21.5 (546) ←
Shroud inner diameter
(b) 17.7 (450) ← 20.5 (520) 24.0 (610) 22.3 (566) ←
Top gap
(c) 0.4 (10) 0.28 (7) ← 0.47 (12) 0.28 (7) ←
Bottom gap
(d) 0.5 (13) ← ← 0.7 (18) 0.5 (13) ←
Side gap
(e) 0.4 (10) ← ← 0.6 (15) 0.4 (10) ←